A small AV receiver gets a redesign: a new front-panel USB-C port that charges a phone at 5 V and 3 A. The team sends the updated file to its certification body, and the reviewer stops at page one, because the safety report still cites EN 60950-1 and EN 60065. Both stopped giving a presumption of conformity under the EU's Low Voltage Directive on 20 December 2020, and the redesign has to be assessed to IEC 62368-1. (The receiver is an illustrative example, not a specific product. Its USB-C port is the worked example below.)
IEC 62368-1 replaced both legacy standards for audio/video, information technology and communication equipment. It applies in the EU as EN IEC 62368-1 under the LVD, in the US and Canada as UL 62368-1 and CSA C22.2 No. 62368-1, and in national adoptions across Asia-Pacific. Since 2023, the edition of EN IEC 62368-1 cited in the Official Journal has lagged behind the IEC editions; the Belgian electrotechnical committee summarized the situation in February 2026. Check the Commission's LVD harmonised standards list before you rely on presumption of conformity.
From prescriptive tables to hazard-based safety
The legacy standards were prescriptive. They gave specific creepage distances for specific voltages and specific tests in a specific order, and a product that followed them was considered safe.
IEC 62368-1 is hazard-based. Clause 0 sets out the model: identify the energy sources in the product, classify them, and put safeguards between each source and the people who could be exposed to it, in proportion to the risk. The outcome may land on the same creepage distance you would have used before. But the route is different, and for a given circuit and user the result can be stricter or looser than the old tables.
The concepts the worked example relies on
Energy source classes
Every circuit is classified by the energy it can deliver. Each hazard has its own clause: electrical energy in Clause 5, fire in Clause 6, thermal energy in Clause 9 and radiation in Clause 10. For electrical energy, Clause 5.2 defines three classes: ES1, not painful though possibly detectable; ES2, painful but not an injury; and ES3, capable of causing injury. Get the classification wrong and every safeguard decision built on it is wrong too.
Safeguards and the people they protect
A safeguard is anything that reduces the risk from an energy source: insulation, barriers and enclosures, current or voltage limiting, protective earthing, or markings and instructions. The standard recognizes three kinds: basic, supplementary and reinforced. How many you need depends on the energy class and on who might be exposed: an ordinary person with no training, an instructed person, or a skilled person.
Components
Safety-critical components (transformers, fuses, connectors and insulating materials) still have to meet their own component standards. Power supplies typically comply with IEC 62368-1 directly or with the recognized component standard for their type. IEC 62368-3 covers DC power transfer through communication cables and ports, such as Power over Ethernet, rather than external power supplies in general. For batteries, Annex M applies, and lithium cells and packs are typically expected to meet IEC 62133-2. Check that component certificates reference current standards, because a certificate issued only to IEC 60950-1 or IEC 60065 may not be acceptable evidence for every requirement.
A worked example: the receiver's USB-C port
Back to the receiver. An ordinary person plugs a cable into the USB-C port during normal use. The port's output, 5 V DC at a modest current, is ES1 on its own: touching the contacts wouldn't hurt.
The classification doesn't stop at the port. Behind it sits a mains-fed power stage at up to 240 V AC, which is ES3. If the safeguard between the two failed, that energy would reach a part an ordinary person touches. So the question the standard asks is what separates the ES3 source from the accessible ES1 part, not what class the port is.
Because an ordinary person can reach the port and the source behind it is ES3, basic insulation alone isn't enough. The design needs reinforced insulation, or basic plus supplementary safeguards, between the mains circuit and the port. Engineers will recognize the result as double insulation, but the standard reaches it through energy class and person type instead of a voltage-band table.
Change the person and the answer changes. If the same circuit were reachable only by a skilled person, after removing screws and past a warning label, the required safeguard would be lower, even though the energy class is the same.
Where the standard catches experienced engineers
Fire enclosures
Clause 6 classifies power sources as PS1, PS2 or PS3 by the power they can deliver into a fault, and the fire safeguards required, including the fire enclosure and its material, depend on that class. Enclosure materials are rated with flame tests such as IEC 60695-11-10, the 50 W test behind the HB and V ratings, and IEC 60695-11-20, the 500 W test behind the 5VA and 5VB ratings. The needle-flame test in IEC 60695-11-5 applies to specific parts, not the whole enclosure. A plastic that passed under 60950-1 doesn't automatically meet the fire enclosure requirements of 62368-1 at the same power level, so check the material's rating against Clause 6 before you commit to tooling.
Accessible surface temperatures
Clause 9 treats heat as an energy source too, classified TS1 to TS3. The allowable temperature of a touchable surface depends on its material, on how long it is likely to be touched and on the part of the body touching it, rather than on a single flat limit. A metal surface touched briefly and a surface held for long periods can end up with quite different limits from the ones 60950-1 gave.
Creepage and clearance
The physics of creepage and clearance hasn't changed. IEC 62368-1 derives clearances (5.4.2) and creepage distances (5.4.3) from the voltages and the pollution degree of the micro-environment involved, rather than from one table. Results often match the legacy values, but not always, so recalculate for each insulation path instead of carrying old distances over.
Products certified under the old standards
New designs go straight to IEC 62368-1. An existing product that changes significantly needs re-evaluation, and legacy reports under 60950-1 or 60065 aren't enough for a new certification. What counts as significant varies by certification body and market, so a conservative internal rule helps: any change that touches a safety-critical circuit, an insulation system or the enclosure triggers re-evaluation. Our guide to getting a hardware product CE marked in under six months shows where that work sits in the schedule, and our comparison of UL, CSA and ETL certification covers the North American side.
Classify the energy, then pick the safeguard
The receiver's new port shows the method in four steps: classify the energy source, identify who can reach the part, then choose the safeguard that separates the two, and only then look up the distances. Start by mapping your existing products' safety-critical circuits onto energy classes and person types, and mark the places where the answer differs from your 60950-1 file. For the exact clause behind a classification, such as the safeguard Clause 5 requires between an ES3 source and an ES1 part an ordinary person can touch, you can ask NavJun about IEC 62368-1 and read the clause it cites.