FCC Part 15 vs. CE EMC Requirements: A Side-by-Side Comparison

FCC Part 15 and the EU EMC rules differ on limits, immunity and approval routes. Where a US-cleared product falls short in Europe, and how to test for both.

Picture a Wi-Fi sensor that ships in the US with a clean FCC grant. A year later the team adds Europe, books an EMC lab, and the first unit resets during the electrostatic discharge test. Nothing in the FCC file warned them, because FCC Part 15 never asked for immunity testing. (That sensor is an illustrative example, not a specific product.)

FCC Part 15 and the EU's EMC rules both limit emissions, so they look like two versions of the same test. They differ in scope, limits, immunity and the route to approval. Each of those differences turns into rework when a team plans for one market and adds the other later.

The differences at a glance

TopicFCC Part 15 (US)EU EMC Directive and RED
What is testedEmissions onlyEmissions and immunity
Legal basis47 CFR Part 15Directive 2014/30/EU, or RED Article 3(1)(b) for radio products
Main standardsLimits in 47 CFR 15.107 and 15.109EN 55032 and EN 55035; EN 301 489-1 plus the radio part, such as -17
Radiated emissionsFrom 30 MHz; Class B at 3 m, Class A at 10 mFrom 30 MHz, limits from CISPR 32
Conducted emissionsAC power line, 150 kHz to 30 MHzMains, 150 kHz to 30 MHz, plus other ports such as wired network ports
ImmunityNoneIEC 61000-4 tests: ESD, radiated RF, fast transients, surge, conducted RF, dips, magnetic fields
Approval, no radioSDoC (47 CFR 2.906); self-testing allowedModule A self-declaration and an EU Declaration of Conformity
Approval, with radioCertification (47 CFR 2.907): accredited lab and TCB grantRED; Notified Body only if harmonised standards are not applied in full (Article 17)
CybersecurityNot part of Part 15RED Delegated Regulation (EU) 2022/30 since 1 August 2025

What each rulebook covers

Part 15 of 47 CFR sets the conditions under which intentional, unintentional and incidental radiators can operate without an individual license. Unintentional radiators produce RF energy as a byproduct, like a processor or a switch-mode power supply. Intentional radiators transmit on purpose, like a Wi-Fi or Bluetooth module. The rules are about emissions: keeping your device from interfering with radio services. A few device categories are exempt from the technical limits under section 15.103.

The EMC Directive (2014/30/EU) asks for two things. Equipment must not generate disturbances that stop other equipment from working, and it must have adequate immunity to the disturbances around it. So CE marking covers emissions and immunity, where Part 15 covers emissions only. For most multimedia and IT products, the harmonised standards are EN 55032 for emissions and EN 55035 for immunity; check the Commission's list of harmonised EMC standards for the editions currently cited.

Radio products are the exception. Equipment with a transmitter falls under the Radio Equipment Directive (2014/53/EU) instead of the EMC Directive, and RED Article 3(1)(b) carries the EMC requirement. In practice that means ETSI EN 301 489-1 plus the part for your radio type, such as EN 301 489-17 for Wi-Fi and Bluetooth.

Emissions: same frequency ranges, different numbers

Under 47 CFR 15.109, radiated limits start at 30 MHz, and the measurement distance depends on the device class. Class B (residential) is measured at 3 meters and Class A (commercial and industrial) at 10 meters. EN 55032 also starts radiated measurements at 30 MHz, with limits taken from CISPR 32. The frequency ranges overlap, but the limit values don't match band for band, and neither rulebook is stricter across the board. Compare both tables for the frequencies your product emits.

Conducted limits work the same way. 47 CFR 15.107 covers 150 kHz to 30 MHz on the AC power line. EN 55032 covers the same mains range and adds limits for other ports, such as wired network ports. A pass on FCC conducted emissions doesn't carry over to EN 55032.

The design rule that falls out of this is simple: for each band, design to whichever limit is tighter. Then one board can pass both labs.

Immunity is where US-first products get caught

Part 15 has no immunity requirement. The EU does, and EN 55035 calls up the IEC 61000-4 test methods: electrostatic discharge, radiated RF fields, electrical fast transients, surge, conducted RF disturbances, voltage dips and interruptions, and power-frequency magnetic fields. Each test has its own levels and pass criteria. Radio products meet the same kinds of tests through EN 301 489-1.

When a product designed for the US adds the EU, the rework usually lands here: ESD protection on exposed connectors, surge suppression on the power input, and filtering that FCC compliance never needed. Adding those parts before tooling is locked costs far less than retrofitting them after. Our guide to EMC design choices that decide a CE marking application walks through the filtering, grounding and layout decisions that matter most.

Two approval routes in the US, self-declaration by default in the EU

Since the FCC's 2017 order (FCC 17-93), published on 2 November 2017, Part 15 devices take one of two routes. The Supplier's Declaration of Conformity (47 CFR 2.906) covers most unintentional radiators: you test the device and keep the records on file. Self-testing is allowed, though many manufacturers still use an accredited lab for defensible data. Certification (47 CFR 2.907) covers intentional radiators and certain other devices. It requires testing at an FCC-recognized accredited lab and a grant from a Telecommunication Certification Body. The accredited-lab requirement belongs to Certification, not to SDoC.

In the EU, most products self-declare under Module A, internal production control (Annex II of the EMC Directive). You run the tests, compile the technical documentation and sign your own EU Declaration of Conformity. Under the EMC Directive alone, most products need no Notified Body. For radio equipment, one becomes mandatory when the harmonised standards aren't applied in full (RED Article 17). Our CE marking overview lists the directives that usually apply together, and our step-by-step EU certification roadmap walks through the full sequence from scoping to the Declaration of Conformity.

One test campaign for both markets

If you're launching in both markets, book one campaign. Start with the EU suite (EN 55032 and EN 55035, or EN 301 489 for a radio product), since it covers more ground. Then add the Part 15 conducted and radiated measurements in the same lab session.

Many accredited labs run both suites, and much of the fixture and setup work overlaps. Ask for a quote on the combined campaign rather than assuming a fixed saving, and ask for two reports: one formatted for the FCC filing and one for the CE technical file.

The same Wi-Fi sensor under two rulebooks

Back to the sensor from the opening. In the US it contains an intentional radiator, so it goes through Certification: accredited lab testing, a TCB grant, radiated emissions measured at 3 meters as a Class B device, and no immunity testing at all. Our FCC Part 15 overview covers the Subpart B and Subpart C rules behind that path.

In the EU, the same hardware sits under the Radio Equipment Directive. Article 3(2) covers the radio itself. Article 3(1)(b) covers EMC, emissions and immunity, through EN 301 489-1 and -17. Article 3(1)(a) covers electrical safety with no lower voltage limit, which is why a battery-powered radio product still needs a safety assessment. The RED cybersecurity requirements (Delegated Regulation (EU) 2022/30) have applied to products like this since 1 August 2025. Depending on the conformity route you choose, a Notified Body may or may not be involved.

The radio hardware can be identical in both markets. The EU file still needs immunity evidence, a safety assessment and a cybersecurity assessment that the US grant never asked for. So a US clearance tells you little about CE readiness: the EU asks for more kinds of evidence as well as different numbers.

Design for the tighter limit, test once for both markets

Compare the limit tables band by band, design in immunity from the first prototype, and run one campaign that produces both reports. That is the shortest path into both markets. When a question comes up along the way, such as whether your US test data covers any part of the RED file, you can ask NavJun and check the Part 15 section or directive article it cites for each point.

This content is provided for informational purposes only and does not constitute legal, regulatory, or compliance advice. Regulatory requirements vary by product, market, and specific circumstances. Always consult qualified experts and official regulatory sources for your specific situation.

← Back to Blog